May I ask which one has the manual for the 2600 clamp meter? I dont need the English one, I want the Chinese one ..

Instructions for using a clamp ammeter, clamp ammeter usage, and clamp ammeter usage methods. Release time: [2008-12-30] Number of visitors: [12] Related categories: [Common problems] Clamp ammeter usage instructions, clamp ammeter usage, and clamp ammeter usage methods.

1. Before using a clamp ammeter, carefully read the instruction manual to determine whether it is an AC or AC/DC dual-purpose clamp ammeter.

2、 The voltage of the tested circuit cannot exceed the value indicated on the clamp meter, otherwise it may cause grounding accidents or electric shock hazards.

3、 The clamp meter can only measure the current of one phase of the wire at a time, and the measured wire should be placed in the center of the clamp window. It is not allowed to clamp multiple phase wires into the window for measurement.

4、 Before measuring with a clamp meter, it is necessary to estimate the magnitude of the measured current before deciding which range to use. If it is impossible to estimate, you can first use the maximum range gear and then switch to a smaller one to obtain accurate readings. Cannot use low current range to measure high current. To prevent damage to the clamp type watch.

5、 The jaws of the clamp type meter should be tightly closed during measurement. If there is any noise after closure, the jaws can be opened and reset once. If the noise still cannot be eliminated, the joint surfaces on the magnetic circuit should be checked for smoothness. If there is dust, they should be wiped clean and tidy.

6、 Due to the low accuracy of the clamp ammeter itself, the following method can be used to measure small currents: first, wrap the wire of the circuit being tested a few times, and then place it into the clamp of the clamp ammeter for measurement. At this time, the current value indicated by the clamp gauge is not the actual value being measured. The actual current should be the reading of the clamp gauge divided by the number of turns the wire is wound.

7、 Do not operate with electricity during maintenance to prevent electric shock. What is the difference between a meter and an ammeter?

metron. meter, metrotre 1AHD: [m ^ "t... r] D.J. [6mi8t *] K.K. [6mit+] n. Chiefly British (noun) [mostly used in the UK] Variant of meter 1 meter 1metremetre 2AHD: [m ^" t... r] D.J. [6mi8t *] K.K. [6mit+] n. Chiefly British (noun) [mostly used in the UK] Variant of meter 2 meter 2metremetre 1AHD: [m ^ "t... r] D.J. [6mi8t] K.K. [6mit+] n. Chiefly British Variant of meter 1metremetre 2AHD: [m ^" t... r] D.J. [6mi8t *] K.K. [6mit+] n. Chiefly British Variant of meter 2metre (Middle English meter『SILVER Official Website SERVICE』