Quenching Oil Flow Meter Heat Treatment Temperature Specs

orificemeter6fecf

DateTime 10/20/2026 Show 153
Quenching Oil Flow Meter Heat Treatment Temperature Specs

Price:¥1.00Quantity:9999

Market Price:¥1.00Reduced Price:¥1.00

Effevtive Time:7/28/2026

Sale Address:SilverProduction Address:Silver automation instruments

Keywords:Quenching Oil Flow Meter Heat Treatment Temperature Specs

Phone:QQ:Click:Wechat: +86 13512131526

Company:SILVER AUTOMATION INSTRUMENTS

『Quenching Oil Flow Meter Heat Treatment Temperature Specs』Related information(flow rotameter|digital flow meter|balo meter|hydraulic flow meter|volumetric meter|positive displacement meter|pitot tube flow meter|displacement meter|cfm meter|variable area flow meter|inline flow meter|differential pressure flow meter|calibrated flow meter|velocity meter|paddle wheel flow meter|oval gear flow meter|anemometer hvac|multiphase flow meter|doppler flow meter|thorpe tube flowmeter|heat flow meter)

Quenching Oil Flow Meter Heat Treatment Temperature Specs

Quick Answer

For quenching oil lines, oval gear and Coriolis flow meters deliver stable readings as oil viscosity shifts with temperature. Silver Instruments supplies meters rated for oil up to 150 °C, with PT100 temperature compensation and 4-20 mA HART output. Select the meter based on your flow range, pipe size DN15 to DN50, and oil type to avoid cracking distortion caused by inconsistent quench flow.


Why Flow Metering Matters for Quenching Oil

In heat treatment shops, quenching oil flow rate directly controls the cooling curve of steel parts. A drop of 5 percent in flow can change hardness by 2 HRC on large shafts. We have seen a fastener plant in Malaysia run oval gear meters for three years without drift because the meter matched the oil viscosity at 80 °C. Most engineers skip measuring oil flow and rely on pump speed, but pump wear and filter clogging change the actual flow. A dedicated flow meter between the heat exchanger and the quench tank gives you real flow data, not an estimate.


Temperature Specs and Viscosity Challenges

Quenching oil typically runs between 60 °C and 120 °C, depending on the grade. At 40 °C a mineral quenching oil shows 22 cSt, but at 100 °C it thins to 4.5 cSt. This viscosity swing can cause turbine or vortex meters to lose accuracy. Oval gear meters, on the other hand, stay within plus minus 0.5 percent of rate across that range if you apply a temperature correction factor. Silver Instruments builds meters with an integral PT100 sensor socket so you can feed a 4-20 mA temperature signal to the PLC and compensate in real time. No separate thermowell required.


Recommended Flow Meter Types

For most quenching oil systems, the SIL-EGM oval gear flow meter series is the first choice. It handles oil up to 150 °C and viscosity from 1 cP to 2000 cP. Standard outputs include pulse, 4-20 mA, and RS485 Modbus. For lines where mass flow measurement is mandatory, for example when you dose quenching oil additive, we recommend the SIL-CMF Coriolis mass flow meter. It reads mass flow directly in kg/h, ignores viscosity changes, and operates from minus 50 °C to 200 °C. A pipe spool of DN15 or DN20 is common, with 316L wetted parts to resist oil degradation products.


Installation and Temperature Compensation

Mount the meter on the discharge side of the circulation pump, after the filter but before the heat exchanger. Keep a straight run of 5 pipe diameters upstream for oval gear meters, although they tolerate less. Because hot oil releases dissolved air, install an air vent upstream to prevent measurement spikes. The PT100 temperature probe inserted into the meter body feeds a signal to the transmitter. Silver Instruments preconfigures the temperature compensation table for common quenching oils such as Gulf 70 and Durixol V35. If you use a special oil, send us the viscosity-temperature curve and we will load it into the meter firmware at no extra charge.

<
Quenching Oil Flow Meter Heat Treatment Temperature Specs
br>

Quick Specs Table for Selection

Here are the key numbers you will need when requesting a quote. Oval gear meter SIL-EGM-15: flow range 2 to 40 L/h, max temperature 150 °C, accuracy 0.5 percent of reading, output 4-20 mA HART, connection G1/2 inch or NPT, wetted parts stainless steel and FKM seals. SIL-EGM-25: 10 to 200 L/h, same specs. Coriolis meter SIL-CMF-15: flow up to 1000 kg/h, temperature up to 200 °C, accuracy 0.1 percent of rate, outputs 4-20 mA, pulse, Modbus. Both lines come with ATEX Zone 1 certification as an option. Because many heat treatment plants in the Middle East and Southeast Asia request Ex d protection, we keep those models in stock.


Real-World Case

Last year a customer in Vietnam upgraded their continuous mesh belt furnace with a SIL-EGM-20 oval gear meter on the quench oil recirculation line. The oil temperature stabilizes at 95 °C during production. Before the meter, they adjusted pump speed manually and checked flow once per shift with a bucket and stopwatch. After installing the meter, they linked the 4-20 mA signal to a paperless recorder and noticed that flow dropped 15 percent over three weeks due to filter fouling. Now they clean filters based on a flow alarm, not a time schedule. Scrap rate from uneven quenching dropped from 2.1 percent to 0.3 percent in six months.


FAQ

Can an oval gear flow meter handle quenching oil at 120 °C continuously?

Yes. The SIL-EGM series uses high-temperature bearings and FKM seals rated for continuous service at 150 °C. We test every meter with hot oil at the factory before shipping.

Do I need to compensate for viscosity changes?

Oval gear meters measure volume, so if viscosity shifts, the leakage gap changes slightly. Adding a PT100 temperature sensor and applying a correction curve in the PLC or flow transmitter keeps accuracy within 0.5 percent. Coriolis meters need no compensation because they measure mass.

What output signals are available for integration with a PLC?

Standard options are 4-20 mA HART, pulse (NPN or PNP), and RS485 Modbus RTU. We can also supply a wireless adapter for MODBUS TCP if your plant uses Ethernet.

Is ATEX certification available for oil flow meters in heat treatment plants?

Yes, we offer ATEX Zone 1 and Zone 2 certified versions for both oval gear and Coriolis meters. The certificate covers gas and dust, which is important because oil mist can create a hazardous area.

How do I request a quote with the correct specifications?

Send us your oil type, normal and maximum operating temperature in °C, flow range in L/h or kg/h, pipe size DN, and required output signal. We will reply with a data sheet and price within one working day.


Need a flow meter calibrated for your specific quenching oil? Send us your oil temperature (°C), pipe size (DN), flow range (L/h or kg/h), and pressure (bar). Our engineers will select the right SIL-EGM or SIL-CMF model and include a preloaded temperature compensation table.